On / Off Control 12V Microwave Sensor High Low Voltage Output

Place of Origin Shenzhen, China
Brand Name Hynall
Certification RED, FCC, RoHS
Model Number HNS101
Minimum Order Quantity 300pcs
Price To be negotiated
Packaging Details Bubble bag + carton. (color box or blister package also available on request)
Delivery Time 3~4 weeks for bulk orders
Payment Terms T/T
Supply Ability 50,000pcs / month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Input Voltage 12V DC (5V & 24V Version Available On Request) Input Current ≥25mA
Control Type On/off Control(high-low Voltage Output) Detection Range Max. 12m In Diameter
Mounting Height 3~6m Operation Temperature -20℃ ~ +70℃
High Light

12v motion sensor switch

,

outdoor motion sensor

,

On / Off Control 12V Microwave Sensor

Leave a Message
Product Description

                    On / Off Control , 12V Microwave Sensor , High - Low Voltage Output

 

This is the basic model for simple on/off control, compared to AC input version, this 12V DC version sensor has smaller size, give less shadow, at the same time, less expensive!

On / Off Control  12V Microwave Sensor High  Low Voltage Output 0

 

Features--

 

5.8GHz C-band microwave.

Input voltage 12V DC (5V & 24V DC version available on request).

Input current:≥25mA.

5V DC high-low voltage output signal.

Super compact, flexible to be integrated into any suitable fixtures.

Dual-processor technology, real Lux-Off function for built-in application.

8 pin DIP switch setting, multiple options to meet different customer demands.

Detection range up to 12m in diameter.

Mounting height: 3~6m.

Operation temperature: -20℃ ~ +70℃

          RoHS compliant.

 

 

Settings--

 

Detection range
Detection range can be reduced by selecting the combination on the DIP switches to fit precisely each application.

On / Off Control  12V Microwave Sensor High  Low Voltage Output 1

 

Hold-time

Hold-time means the time period to keep the lamp on 100% after motion detected.

*when hold-time set as 3s, sensor enters into test mode, this test mode is mainly for users to choose the desired detection range. In this mode, the daylight sensor is disabled, when there is no motion, fixture keeps off, when there is motion detected, fixture keeps a cycle of 3s on and 2s off.

On / Off Control  12V Microwave Sensor High  Low Voltage Output 2

 

Daylight sensor

Daylight sensor means the daylight threshold to enable or disable the sensor function.

"Disable”: The sensor works always, even during daylight.

"50lux, 25lux": The sensor works only in twilight.

"10lux, 2lux": The sensor works only in the dark.

On / Off Control  12V Microwave Sensor High  Low Voltage Output 3

 

Detection pattern--

 

On / Off Control  12V Microwave Sensor High  Low Voltage Output 4

 

Lux-Off function--

Utilizing the Dual-processor technology, this sensor can tell the difference of natural light and artificial light(lamp) from behind the diffuser, then switch off automatically whenever the artificial light is not required(ambient light is bright enough).

 

This is the REAL& INTELLIGENT lux-off sensor for built-in installation.

 

Note: Lux-Off sampling time--30s

On / Off Control  12V Microwave Sensor High  Low Voltage Output 5